BCWNM - GC 1300
- MSDS: BCWNM
- Manufacturer: GOAL CHEMICAL SEALANTS CORP
- Product Name: GC 1300
- National Stock Number: 5970-00-058-8887
Product Identification
Product ID:GC 1300
MSDS Date:01/01/1987
FSC:5970
NIIN:00-058-8887
MSDS Number: BCWNM
Responsible Party
Emergency Phone: 213-269-0461
Cage: 04011
Contractor
Telephone: 213-269-0461
Cage: 04011
Ingredients
PIGMENTS
Fraction By Weight: 36.0%
LEAD PEROXIDE (LEAD DIOXIDE), (OSHA PEL FROM 29CFR
CAS: 1309-60-0
RTECS: OG0700000
Fraction By Weight: 2.0%
OSHA PEL 0.05 MG/M3 (PB)
ACGIH TLV: 0.15 MG/M3(PB); 8990
POLYSULFIDE POLYMER
Fraction By Weight: 60.0%
ADDITIVES
Fraction By Weight: 2.0%
Hazards
Effects of Overexposure:MAY CAUSE SKIN & EYE IRRITATION
First Aid
First Aid:IN CASE OF EYE CONTACT,FLUSH AFFECTED AREA WITH WATER,SEE A
PHYSICIAN
Fire Fighting
Flash Point:>400F/204C (O.C)
Extinguishing Media:DRY CHEMICALS,WATER
Fire Fighting Procedures:NONE
Unusual Fire/Explosion Hazard:NONE
Accidental Release
Spill Release Procedures:SPAT UP EXCESS,CLEAN RESIDUE WITH SOLVENT &
CLOTH METHYL ETHYL KETONE
Handling
Handling and Storage Precautions:NORMAL TEMPERATURES,80F OR BELOW FOR
STORING
Other Precautions:NONE
Exposure Controls
Respiratory Protection:SELF CONTAINED BREATHING APPARATUS
Ventilation:AS REQUIRED TO CONTROL THE TLV IN AIR
Protective Gloves:RUBBER
Eye Protection:SAFETY GOGGLES
Supplemental Safety and Health
THE ITEM IS TYPE II AND CLASS 2 IN MIL-S-8516 MILITARY SPECIFICATION
Chemical Properties
HCC:N1
Boiling Pt:B.P. Text:N.A.
Spec Gravity:1.2
Stability
Stability Indicator/Materials to Avoid:YES
OXIDIZING MATERIALS,FLAMMABLES,ACIDS,ALKALINES
Disposal
Waste Disposal Methods:INCINERATE IN A FURNACE UNDER APPROVED
CONTROLLED PROCEDURES
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.